4th Axis rough treatment
Hi All, This one is rather embarassing as its the result of rough treatment when removing the 4th Axis to free up room on the bed.
Now I have finished cutting my 2D stuff I have reattached the 4th Axis to the bed and the memory came back to me from when i disconnected the communication cable a few months ago with an ape like twisting pulling motion!!!!!

Needless to say it hasn't done the connections any favours and I now have 4 pairs of wires that should be connected to the contacts within the plug. I'm pretty sure I can get it all back together again as nothing is actually broken but would like some info on:

How the wires are paired
Configuration of the contacts
Attachments:
Ashamed of myself!
Ashamed of myself!
Denford 4th Axis cable.jpg (65.02 KiB) Viewed 19875 times
Re: 4th Axis rough treatment
Ah! doesn't look like I will be able to fix this afterall as i've damaged the plug trying to get the pin contacts out. looks like i'll be ordering a replacement cable. :oops:
User avatar
CNC Guru
CNC Guru
Re: 4th Axis rough treatment
4th Axis plug

Old Version
Pin No Colour
A BLACK
B ORANGE
D RED
E YELLOW


New Version
Pin No Colour
A RED
B BLUE
D BLACK
E GREEN
CNC Guru
CNC Guru
Re: 4th Axis rough treatment
If it's a 8 wire motor then use the following.

Red & Blue ------------------ Red
Red/White & Blue/White ------- Blue
Green/White & Black/White ---- Black
Green & Black -----------------Green