my triac keeps tripping the RCD when I turn it on
traced it back to wire 21 coming out of SRR relay, anyone know what this wire is attached to?
wire 21 on SRR??
Moderators: Martin, Steve, Mr Magoo
Re: wire 21 on SRR??
According to the list of wire numbers I've made up, 21 is one of the spindle motor power wires. 20 being the other power wire.
Re: wire 21 on SRR??
Also consider having an electrician check the functionality of the RCD. I had mine go bad but thought it was my inverter welder which tripped the RCD when turned on. The welder supplier checked it out and it all tested fine so I called in the electrician who diagnosed the RCD was faulty and replaced it and all good since. The electrician did say it was a good idea to test the RCDs with their test button every 3 months or so.