Search found 4 matches

by ChrisQ
Fri 15 Feb , 2019 18:00 pm
Forum: Cyclone
Topic: M10, M11 chuck commands causing cycle stop
Replies: 5
Views: 7981

Re: M10, M11 chuck commands causing cycle stop

Hi Martin i have solved the problem, by tracing the problem through the diagnostics it turned out to be air pressure related. when i checked the regulator i found the gauge was not telling the truth and i had managed to set an air pressure that meant everything was happy until the air cylinder was a...
by ChrisQ
Thu 14 Feb , 2019 10:35 am
Forum: Cyclone
Topic: M10, M11 chuck commands causing cycle stop
Replies: 5
Views: 7981

Re: M10, M11 chuck commands causing cycle stop

Hi Martin
thanks, have already done both of those.
do you know how the M codes are set and if it's possible to look at the set up,and change them?
only other thing i can think of is to wipe the controller and re-install everything but that seems a bit drastic
by ChrisQ
Wed 13 Feb , 2019 13:22 pm
Forum: Cyclone
Topic: M10, M11 chuck commands causing cycle stop
Replies: 5
Views: 7981

Re: M10, M11 chuck commands causing cycle stop

Hi Martin
thanks for your suggestion, sadly it didn't make any difference.
by ChrisQ
Tue 12 Feb , 2019 17:20 pm
Forum: Cyclone
Topic: M10, M11 chuck commands causing cycle stop
Replies: 5
Views: 7981

M10, M11 chuck commands causing cycle stop

Hi. I have a Cyclone P with a Fanuc OTC control with a Gamet power chuck fitted. I am using a bar puller running from a sub program for small batch production. The first time I ran the job everything worked fine and I was able to produce 200 parts without a hitch. I have just set up to do the job ag...