Re: mirac pc software problem on intel pentium 4
sir the RS232 lead is ok because we check it on old computer that is currently working on window 95. but when we change to new system it hang on initializing mint 3.28. sir i think the problem is with ibm.rs2 command because our pc is intel not ibm. intel pentium 4 single processor running window 98...
- Fri 10 Jul , 2015 20:53 pm
- Forum: Software
- Topic: mirac pc software problem on intel pentium 4
- Replies: 2
- Views: 4881
mirac pc software problem on intel pentium 4
we have old computer which has ram of 16mb and operating system of window 95 connected with mirac pc and desktop tour keypad through flstep.exe. currently it is runing on that system but that system is too slow to boot and sometime the old pc didn't start due to some hardware such as keyboard proble...
- Thu 02 Jul , 2015 12:22 pm
- Forum: Triac
- Topic: triac om c controller allarm on helcal interpolation
- Replies: 1
- Views: 2958
Re: triac om c controller allarm on helcal interpolation
i find the solution and want to share.
changing the parameter no 910 to 00001000.
changing the parameter no 910 to 00001000.
- Wed 01 Jul , 2015 11:18 am
- Forum: Triac
- Topic: triac om c controller allarm on helcal interpolation
- Replies: 1
- Views: 2958
triac om c controller allarm on helcal interpolation
G03 X45.832 Y52.236 Z2.12 I1.198 J1.061 F1000
the above helical interpolation give me alarm how to do helical interpolation on fanuc triac om c controller
the above helical interpolation give me alarm how to do helical interpolation on fanuc triac om c controller
- Wed 22 Apr , 2015 20:01 pm
- Forum: Mirac
- Topic: mirac dos and window98 era
- Replies: 4
- Views: 9890
mirac dos and window98 era
is there any way to run the mirac software on window 7.
- Wed 22 Apr , 2015 16:05 pm
- Forum: Software
- Topic: mirac and triac miller software for window 7
- Replies: 1
- Views: 3992
mirac and triac miller software for window 7
we have mirac lath and fanuc triac miller cnc which are connected to old pc and operating system is window 95 which is old one and some issue with old pc. we need to update the pc to new one but the software the mirac and fanuc triac miller is runing on window 95. we need new software for mirac and ...
- Fri 27 Mar , 2015 14:04 pm
- Forum: Electronics
- Topic: fanuc om-c controller parameter and diagnostic list descript
- Replies: 3
- Views: 7692
Re: fanuc om-c controller parameter and diagnostic list desc
thank sir i already read it when i lost all my parameter last time and then you help me by providing 2=osp servo motor parameter for triac fanuc atc vmc. but this list is limited to only 450 to 464 diagnostic and 700 to 708 parameter. i want complete list of parameter from 1 to 8355 with description...
- Fri 27 Mar , 2015 10:24 am
- Forum: Electronics
- Topic: fanuc om-c controller parameter and diagnostic list descript
- Replies: 3
- Views: 7692
fanuc om-c controller parameter and diagnostic list descript
i need fanuc omc controller parameter and diagnostic list with description.so that what different parameter and diagnostic are doing.
- Thu 26 Mar , 2015 14:01 pm
- Forum: Triac
- Topic: denford triac fanuc atc om-c parameter lost and alarm 510 ..
- Replies: 18
- Views: 13132
Re: denford triac fanuc atc om-c parameter lost and alarm 51
thank you sir martin all alarm are clear now the machine is running now with new parameter for 2-osp servo motor.
its a good learning process journey with you sir.
sir are you den ford employ?
thanks again for your cooperation.
its a good learning process journey with you sir.
sir are you den ford employ?
thanks again for your cooperation.
- Wed 25 Mar , 2015 17:46 pm
- Forum: Triac
- Topic: denford triac fanuc atc om-c parameter lost and alarm 510 ..
- Replies: 18
- Views: 13132
Re: denford triac fanuc atc om-c parameter lost and alarm 51
sir is there any way to confirm it from motor model number (AO6B-0371-B010#7000 ) which fanuc osp servo motor it is. i just check in the given two link that given servo motor model (AO6B-0371-B010#7000 ) is 2-osp but in one link it say it is fitted with a 2500 pulse coder is it a standard or the pul...
- Wed 25 Mar , 2015 15:53 pm
- Forum: Triac
- Topic: denford triac fanuc atc om-c parameter lost and alarm 510 ..
- Replies: 18
- Views: 13132
Re: denford triac fanuc atc om-c parameter lost and alarm 51
ok sir i will check these parameter on machine tomorrow they are different then the one i have downloaded from net. also sir you send me the machine info yesterday in that the motor model is AO6B-0371-B010#7000 and driver model is AO6B-6058-H331. is this (AO6B-0371-B010#7000 ) motor model is 2-osp,1...
- Wed 25 Mar , 2015 15:00 pm
- Forum: Triac
- Topic: denford triac fanuc atc om-c parameter lost and alarm 510 ..
- Replies: 18
- Views: 13132
Re: denford triac fanuc atc om-c parameter lost and alarm 51
sir i did what you said reset the memory and then enter the value in above given sequence. the only alarm clear from this process is 531 the other two alarm is still there 401 and 420 i did an experiment with parameter value 593 to 596 which is set to 100. i change that parameter value 430 the contr...
- Wed 25 Mar , 2015 11:08 am
- Forum: Triac
- Topic: denford triac fanuc atc om-c parameter lost and alarm 510 ..
- Replies: 18
- Views: 13132
Re: denford triac fanuc atc om-c parameter lost and alarm 51
sir after entering the parameter and diagnostic from above attached file now the operator panel is now working but still there is some alarm alarm 521 z axis over travel which i will clear with (can and p) press but the other two alarm are still there 401 and 420 the bazaar effect is that when i res...
- Tue 24 Mar , 2015 16:31 pm
- Forum: Triac
- Topic: denford triac fanuc atc om-c parameter lost and alarm 510 ..
- Replies: 18
- Views: 13132
Re: denford triac fanuc atc om-c parameter lost and alarm 51
thank you sir i am impressed how you find that because it's 19 year old record i think.
i will enter these parameter tomorrow and inform you.
thanks again for your cooperation
i will enter these parameter tomorrow and inform you.
thanks again for your cooperation
- Tue 24 Mar , 2015 13:51 pm
- Forum: Triac
- Topic: denford triac fanuc atc om-c parameter lost and alarm 510 ..
- Replies: 18
- Views: 13132
Re: denford triac fanuc atc om-c parameter lost and alarm 51
machine serial no is E04788B TRIAC FANUC 1996 software version plc 3.70l we haven't diagnostic setting for that from denford we have parameter list but don't have diagnostic list can you guid us how to give diagnostic setting. 900 parameter list is also missing in denford manuals.the company didn't ...
- Tue 24 Mar , 2015 10:19 am
- Forum: Triac
- Topic: denford triac fanuc atc om-c parameter lost and alarm 510 ..
- Replies: 18
- Views: 13132
Re: denford triac fanuc atc om-c parameter lost and alarm 51
sir the 510 and 521 alarm are clear after i enter the parameter 700 to 707. but the following alarm are still there 531 over travel -z 401 servo alarm y axis vrdx off 420 servo alarm y axis excess error another thing you mention is diagnostics setting.when i enter the 450 diagnostic 00000001 it didn...
- Mon 23 Mar , 2015 16:36 pm
- Forum: Triac
- Topic: denford triac fanuc atc om-c parameter lost and alarm 510 ..
- Replies: 18
- Views: 13132
Re: denford triac fanuc atc om-c parameter lost and alarm 51
thanks i will enter these value tomorrow. but before that i am bit confuse regarding the stoke limit parameter 700 to 707. it says for 700 (Stroke limit 1 located right to ref. point X axis). can you explain whats mean by reference point x axis because after clear the machine memory how the machine ...
- Mon 23 Mar , 2015 13:36 pm
- Forum: Triac
- Topic: denford triac fanuc atc om-c parameter lost and alarm 510 ..
- Replies: 18
- Views: 13132
denford triac fanuc atc om-c parameter lost and alarm 510 ..
kindly help me i am new and not know much about different parameter and there function. i replace old battery and lost all my parameter i manually enter the parameter 1 to 8393 (see the attached file) except the one with p_ _ _ _ _ _ _ _ because i didn't know what to enter.but still getting the foll...