phew.. that mean my programming was right!?
We are on netwrok here, will need to run it past our IT dept.
Thanks
Will be in touch!
Search found 20 matches
- Tue 21 Aug , 2012 15:38 pm
- Forum: VR Turning - All Versions
- Topic: Denford VR Turn freeze on simulation - G42
- Replies: 5
- Views: 13179
- Tue 21 Aug , 2012 8:45 am
- Forum: VR Turning - All Versions
- Topic: Denford VR Turn freeze on simulation - G42
- Replies: 5
- Views: 13179
Re: Denford VR Turn freeze on simulation - G42
Simple program using G90 [BILLET X26 Z50 N10 G21 G40 G97 G99 N20 G28 U0.0 W0.0 N30 M06 T0101 (Roughing tool) N40 G96 S200 N50 M13 S1000 N60 G50 S3000 N70 G00 X27.0 Z0.0 N80 G01 X-1.0 F0.05 N90 G00 X27.0 Z2.0 N100 G90 X24 Z-26.5 N100 G90 X22 Z-24 N110 G90 X20 Z-23 N120 G90 X18 Z-13 N130 G90 X16 Z-11....
- Mon 20 Aug , 2012 16:03 pm
- Forum: VR Turning - All Versions
- Topic: Denford VR Turn freeze on simulation - G42
- Replies: 5
- Views: 13179
Denford VR Turn freeze on simulation - G42
Having problems when using G42 on some teaching programs we use in Denford VR Turn. For some reason the program will run up to a certain point, then freeze the simulation! I have checked for typo's in the program but cant see any typical errors. :? Close the software down and reload, but on reload r...
- Wed 25 May , 2011 15:45 pm
- Forum: Cyclone
- Topic: Alarm - 1021 x motor o/heat
- Replies: 5
- Views: 5607
Re: Alarm - 1021 x motor o/heat
Machine has been left off overnight so assume overheating is not a problem!
hmmm.. time to get the hammer out!
hmmm.. time to get the hammer out!
- Wed 25 May , 2011 10:16 am
- Forum: Cyclone
- Topic: Alarm - 1021 x motor o/heat
- Replies: 5
- Views: 5607
Alarm - 1021 x motor o/heat
Hi again guys!
Having more problems with our Harrison TU150..
Showing an alarm 1021 after homing machine..
Give it time to rest and rehome but then pops up with the alarm again!
Cant use the machine at all!
Any ideas?
Mark
Having more problems with our Harrison TU150..
Showing an alarm 1021 after homing machine..
Give it time to rest and rehome but then pops up with the alarm again!
Cant use the machine at all!
Any ideas?
Mark
- Thu 31 Mar , 2011 9:51 am
- Forum: Cyclone
- Topic: Denford TU150
- Replies: 3
- Views: 3897
Re: Denford TU150
Yes.. spot on!
Cleared the fault and the memory.. which has got rid of some dead programs i needed to sort through, so good news all around!
Thanks again, your my hero!
Mark
Cleared the fault and the memory.. which has got rid of some dead programs i needed to sort through, so good news all around!
Thanks again, your my hero!
Mark
- Wed 30 Mar , 2011 15:30 pm
- Forum: Cyclone
- Topic: Denford TU150
- Replies: 3
- Views: 3897
Re: Denford TU150
Thanks for the info.. will give it a try and get back!
Thanks
Mark
Thanks
Mark
- Wed 30 Mar , 2011 14:24 pm
- Forum: Cyclone
- Topic: Denford TU150
- Replies: 3
- Views: 3897
Denford TU150
Hi guys.. looking for help again!! Got an alarm showing 101 P/S.. Looking at our manual it offers the following: The power was turned off while rewriting the contents of the memory in the part program storage and editing operation. When this alarm is generated, set the setting data PWE to 1 and turn...
- Fri 07 Jan , 2011 14:46 pm
- Forum: Cyclone
- Topic: Workshift error after running graphics
- Replies: 3
- Views: 3559
Re: Workshift error after running graphics
From what im told, it has been a fault that came with the machines originally but not sure if machines where new at that time!
Oh well!!
Oh well!!
- Thu 06 Jan , 2011 21:01 pm
- Forum: Cyclone
- Topic: Workshift error after running graphics
- Replies: 3
- Views: 3559
Workshift error after running graphics
Hi again gents.. Hoping you can help with a long standing fault which has been accepted for far too long! Machine info: Harrison TU150P Model A Built 1994 Serial No. TP0015 Software ver. 7.7D GE Fanuc OT Machine shows a workshift error in z of 3.9mm every time graphics is run! We currently have to s...
- Thu 16 Dec , 2010 16:47 pm
- Forum: Cyclone
- Topic: Harrison TU150P Fault
- Replies: 18
- Views: 11805
Re: Harrison TU150P Fault
After some long reading of the machine manual, the advice from this forum and giving myself a mental beating, we have found the error!
The 544 and 545 parameters have now been reset to zero and the machine is working! Been looking at the diagnosic pages!
Thanks for all your help!
Mark
The 544 and 545 parameters have now been reset to zero and the machine is working! Been looking at the diagnosic pages!
Thanks for all your help!
Mark
- Wed 15 Dec , 2010 17:31 pm
- Forum: Cyclone
- Topic: Harrison TU150P Fault
- Replies: 18
- Views: 11805
Re: Harrison TU150P Fault
Have just powered up to check x axis movement during power on!
Each time it powers up it does seem to move or even twitch -0.1 or similar.. press alarm reset and i repeats!
Each time it powers up it does seem to move or even twitch -0.1 or similar.. press alarm reset and i repeats!
- Wed 15 Dec , 2010 15:25 pm
- Forum: Cyclone
- Topic: Harrison TU150P Fault
- Replies: 18
- Views: 11805
Re: Harrison TU150P Fault
have check parameters 544 and 545 and both are at showing all zeros
- Wed 15 Dec , 2010 15:21 pm
- Forum: Cyclone
- Topic: Harrison TU150P Fault
- Replies: 18
- Views: 11805
Re: Harrison TU150P Fault
Have checked F1 - F2 on INPUT UNIT F1, F6 - F9 between TRUNKING E and D F12 - F13 on POWER UNIT During bootup: The SO and SI LED's illumiate on the OT-A Control board The XER and ZER LED's flash on, then off again! The SI LED switches off leaving just the SO LED on. Have located the drive boards (pi...
- Tue 14 Dec , 2010 17:30 pm
- Forum: Cyclone
- Topic: Harrison TU150P Fault
- Replies: 18
- Views: 11805
Re: Harrison TU150P Fault
Looking at manual again..
Alarm 410
Servo alarm
Contents: In x-axis, the position deviation amount during stop is greater than the setting value.
Remarks: T or M.
It also provides a Note: It is necessary to set the limit value to newly added parameter no 593 - 596.
Alarm 410
Servo alarm
Contents: In x-axis, the position deviation amount during stop is greater than the setting value.
Remarks: T or M.
It also provides a Note: It is necessary to set the limit value to newly added parameter no 593 - 596.
- Tue 14 Dec , 2010 17:15 pm
- Forum: Cyclone
- Topic: Harrison TU150P Fault
- Replies: 18
- Views: 11805
Re: Harrison TU150P Fault
Have 2 of these TU's here so have run them at same time to compare! No differances between them during boot up, but when checking the LED's in the back we have! Our faulted machine has XDFR and ZDFR LED's illuminated, but our working machine also has XER and ZER! Does that point me in any direction?...
- Tue 14 Dec , 2010 11:05 am
- Forum: Cyclone
- Topic: Harrison TU150P Fault
- Replies: 18
- Views: 11805
Re: Harrison TU150P Fault
Machine info is as follows:
Harrison TU150P
Built 1994
Serial No. TP0015
Software ver. 7.7D
GE Fanuc OT
Manual says that its model A
Harrison TU150P
Built 1994
Serial No. TP0015
Software ver. 7.7D
GE Fanuc OT
Manual says that its model A
- Fri 10 Dec , 2010 15:45 pm
- Forum: Cyclone
- Topic: Harrison TU150P Fault
- Replies: 18
- Views: 11805
Re: Harrison TU150P Fault
No brake in the system!
Looked at the parameters, 593 and 594 show as zeros
Have checked out our machine manual and those numbers dont show up!
What actual figures should be inputed into the parametersproduce the 10mm jump?
Thanks
Mark
Looked at the parameters, 593 and 594 show as zeros
Have checked out our machine manual and those numbers dont show up!
What actual figures should be inputed into the parametersproduce the 10mm jump?
Thanks
Mark
- Fri 10 Dec , 2010 14:19 pm
- Forum: Cyclone
- Topic: Harrison TU150P Fault
- Replies: 18
- Views: 11805
Re: Harrison TU150P Fault
Thanks for the quick reponse admin..
Have checked all fuses we know of.. shown as F1, F6 - F9! No fault!
Check switched off and reset all breakers!
Rebooted machine and still showing same error message!
Any other advice?
Mark
Have checked all fuses we know of.. shown as F1, F6 - F9! No fault!
Check switched off and reset all breakers!
Rebooted machine and still showing same error message!
Any other advice?
Mark
- Fri 10 Dec , 2010 12:06 pm
- Forum: Cyclone
- Topic: Harrison TU150P Fault
- Replies: 18
- Views: 11805
Harrison TU150P Fault
Hi Guys.. Can you help? Our TU150P is having a student created problem.. it has an "410 servo alarm: x exess err" displayed on screen. From what i understand, after setting z zero to the billet, he was homing the machine but pressed x+ which ploughed the tool into the job! Tried the IT solution" tur...